BGSRW - BATTERY TERMINAL PROTECTOR

Product Identification

Product ID:BATTERY TERMINAL PROTECTOR
MSDS Date:01/22/1990
FSC:6850
NIIN:01-288-3054
MSDS Number: BGSRW

Responsible Party
BARNES GROUP INC BOWMAN DISTRIBUTION DIV
850 E 72ND ST
CLEVELAND, OH 44101
US

Emergency Phone: 216-391-7200

Info Phone: 216-391-7200 / FAX 216-391-1121

Cage: 05573

Contractor
BOWMAN DISTRIBUTION, BARNES GROUP INC
CLEVELAND, OH 44114-1824 US

Telephone: 216-416-7200

Cage: 05573

Ingredients

XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 5-10%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 10-15%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPELLANT (PROPANE/ISOBUTANE/N-BUTANE)

Fraction By Weight: 23%

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CAN CAUSE NASAL AND RESPIRATORY
IRRITATION. CHRONIC: PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGEHAS
BEEN REPORTED. OVEREXPOSURE TO THESSE CHEMICALS HAS BEEN FOUND TO
CAUSE DAMAGE TO LUNGS, HEART , LIVER, KIDNEYS AND SPLEEN IN
LABORATORY ANIMALS. LIVER ABNORMALITIES HAVE BEEN FOUND IN HUMANS.
Explanation of Carcinogenicity:METHYLENE CHLORIDE IS REPORTED TO CAUSE
CANCER IN LABORATORY ANIMALS.
Effects of
Overexposure:DIZZINESS,WEAKNESS,FATIGUE,NAUSEA,HEADACHE,POSSIBLE
UNCONSCIOUSNESS & EVEN ASPHYSXIATION.

First Aid

First Aid:IF AFFECTED,REMOVE INDIVIDUAL TO FRESH AIR. IF BREATHING IS
DIFFICULT,ADMINISTER OXYGEN.IF BREATHING HAS STOPPED,GIVE
ARTIFICIAL RESPIRATION. KEEP PERSON WARM,QUIET & GET MEDICAL
ATTENTION.

Fire Fighting

Flash Point Method:CC
Flash Point:-0F,-18C
Lower Limits:1.0
Extinguishing Media:CO*2,DRY CHEMICAL, OR ALCOHOL FOAM.
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE;WATER MAY BE
USED TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILD-UP &
POSSIBLE AUTOIGNITION OR EXPLOSION,EXPOSED TO HIGH HEA
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL
ALONG THE GROUND & IGNITED BY PILOT LIGHTS,FLAMES,ETC.

Accidental Release

Spill Release Procedures:ABSORB LIQUID ON PAPER,VERMICULITE,FLOOR
ABSORBENT OR OTHER ABSORBENT MATERIAL & TRANSFER TO A CLOSED
CONTAINER. ELIMINATE ALL IGNITION SOURCES.

Handling

Handling and Storage Precautions:DO NOT STORE IN AREAS ABOVE 120F OR IN
DIRECT SUNLIGHT OR NEAR HEAT OR OPEN FLAMES.

Exposure Controls

Respiratory Protection:WHEN TLV EXCEEDED,USE NIOSH/MSHA JOINTLY
APPROVED SELF-CONTAINED BREATHING APPARATUS WITH A FULL PIECE
OPERATED IN PRESSURE DEMAND.
Ventilation:LOCAL EXHAUST.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL GOGGLES.
Supplemental Safety and Health

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:104-281F
Vapor Pres:340
Spec Gravity:0.9
Appearance and Odor:LIQUID,RED GREASE,SOLVENT ODOR.
Percent Volatiles by Volume:80-85

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT,SPARKS OR OPEN FLAMES.
Hazardous Decomposition Products:NONE STATED.

Disposal

Waste Disposal Methods:MATERIAL COLLECTED ON ABSORBENT MATERIAL MAY BE
DEPOSITED IN A POSTED TOXIC SUBSTANCE LANDFILL IN ACCORDANCE WITH
LOCAL,STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.